Published August 2008 | Version v1
Journal article

Inverse problem of estimating transient heat transfer rate on external wall of forced convection pipe

  • 1. Clean Energy Center, Department of Mechanical Engineering, Kun Shan University, Yung-Kang City, Tainan 710-03, Taiwan (China)

Description

In this study, a conjugate gradient method based inverse algorithm is applied to estimate the unknown space and time dependent heat transfer rate on the external wall of a pipe system using temperature measurements. It is assumed that no prior information is available on the functional form of the unknown heat transfer rate; hence, the procedure is classified as function estimation in the inverse calculation. The accuracy of the inverse analysis is examined by using simulated exact and inexact temperature measurements. Results show that an excellent estimation of the space and time dependent heat transfer rate can be obtained for the test case considered in this study

Availability note (English)

Available from http://dx.doi.org/10.1016/j.enconman.2008.02.007

Additional details

Identifiers

DOI
10.1016/j.enconman.2008.02.007;
PII
S0196-8904(08)00079-4;

Publishing Information

Journal Title
Energy Conversion and Management
Journal Volume
49
Journal Issue
8
Journal Page Range
p. 2117-2123
ISSN
0196-8904
CODEN
ECMADL

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
40016408
Subject category
S29: ENERGY PLANNING, POLICY AND ECONOMY;
Descriptors DEI
ACCURACY; ALGORITHMS; FORCED CONVECTION; SIMULATION; TEMPERATURE MEASUREMENT; TIME DEPENDENCE
Descriptors DEC
CONVECTION; ENERGY TRANSFER; HEAT TRANSFER; MASS TRANSFER; MATHEMATICAL LOGIC

Optional Information

Copyright