Test results and perspectives of the cluster test program
Description
The Cluster Test Facility has been constructed and successfully tested at the Japan Atomic Energy Research Institute (JAERI) for the development of superconducting tokamak toroidal coils. The Cluster Test Coils are 20 mj, NbTi, pool-cooled coils. During the first test operation, the two coils were charged successfully to the rated current value of 2.145 amp without quenching. The data obtained during the cool down were significant. This information pertains mainly to the efficiency of the cooling surface and thermal properties of the coil legs composed of stainless steel and glass epoxy. Results of strain measurements during the charging tests indicated a serious problem of analytical calculations. This problem arises primarily from the difficulty of defining the mechanical properties of winding-structure interface. The first test module coil is a 10 T, Nb/sub 3/Sn coil. 7 refs
Additional details
Publishing Information
- Journal Title
- IEEE Trans. Magn.
- Journal Volume
- MAG-17
- Journal Issue
- 5
- Series
- IEEE Trans. Magn.
- Journal Page Range
- 2234-2237
- ISSN
- 0018-9464
Conference
- Title
- 7. international conference on magnet technology.
- Dates
- 30 Mar - 3 Apr 1981.
- Place
- Karlsruhe (Germany, F.R.).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14799505
- Subject category
- S75: CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY; S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- JAERI; MECHANICAL PROPERTIES; NIOBIUM BASE ALLOYS; PERFORMANCE TESTING; POOL BOILING; STRAINS; SUPERCONDUCTING COILS; TITANIUM ALLOYS
- Descriptors DEC
- ALLOYS; BOILING; ELECTRIC COILS; ELECTRICAL EQUIPMENT; EQUIPMENT; JAPANESE ORGANIZATIONS; NATIONAL ORGANIZATIONS; NIOBIUM ALLOYS; PHASE TRANSFORMATIONS; TESTING; TRANSITION ELEMENT ALLOYS
Optional Information
- Secondary number(s)