Design of a constant fraction discriminator for the VFAT3 front-end ASIC of the CMS GEM detector
Creators
- 1. CERN, Geneva (Switzerland)
- 2. INFN Bari and University of Bari, Bari (Italy)
- 3. Helwan University and CTP, Cairo (Egypt)
- 4. Texas A and M University at Qatar, Doha (Qatar)
- 5. Academy of Scientific Research and Technology - Egyptian Network of High Energy Physics, ASRT-ENHEP, Cairo (Egypt)
- 6. University of Florida, Gainesville (United States)
- 7. National Center for Physics, Quaid-i-Azam University Campus, Islamabad (Pakistan)
- 8. Institute for Nuclear Research and Nuclear Energy, Sofia (Bulgaria)
- 9. Peking University, Beijing (China)
- 10. Saha Institute of Nuclear Physics, Kolkata (India)
Description
In this work the design of a constant fraction discriminator (CFD) to be used in the VFAT3 chip for the read-out of the triple-GEM detectors of the CMS experiment, is described. A prototype chip containing 8 CFDs was implemented using 130 nm CMOS technology and test results are shown
Availability note (English)
Available from http://dx.doi.org/10.1088/1748-0221/11/01/C01023Additional details
Identifiers
Publishing Information
- Journal Title
- Journal of Instrumentation
- Journal Volume
- 11
- Journal Issue
- 01
- Journal Page Range
- p. C01023
- ISSN
- 1748-0221
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47072357
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CMS DETECTOR; DESIGN; ELECTRON MULTIPLIER DETECTORS; READOUT SYSTEMS; SEMICONDUCTOR DEVICES
- Descriptors DEC
- MEASURING INSTRUMENTS; RADIATION DETECTORS