Description

In this work the design of a constant fraction discriminator (CFD) to be used in the VFAT3 chip for the read-out of the triple-GEM detectors of the CMS experiment, is described. A prototype chip containing 8 CFDs was implemented using 130 nm CMOS technology and test results are shown

Availability note (English)

Available from http://dx.doi.org/10.1088/1748-0221/11/01/C01023

Additional details

Publishing Information

Journal Title
Journal of Instrumentation
Journal Volume
11
Journal Issue
01
Journal Page Range
p. C01023
ISSN
1748-0221

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47072357
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
CMS DETECTOR; DESIGN; ELECTRON MULTIPLIER DETECTORS; READOUT SYSTEMS; SEMICONDUCTOR DEVICES
Descriptors DEC
MEASURING INSTRUMENTS; RADIATION DETECTORS