Three-dimensional beam scanning for proton therapy

  • 1. National Inst. of Radiological Sciences, Chiba (Japan). Div. of Physics
  • 2. Tsukuba Univ., Sakura, Ibaraki (Japan). Inst. of Basic Medical Sciences

Description

An important goal of radiation therapy is to localize the dose in the target volume. The favorable properties of proton beams, such as a well-determined range and straight penetration through tissues, have been used to develop a three-dimensional beam scanning method. This system consists of a two-dimensional beam scanning system and an energy degrader of variable thickness which are both controlled by a beam monitor that is connected to a minicomputer. A typically conformed dose distribution with the three-dimensional beam scanning system was measured by a specially designed multiwire ionization chamber. The results have shown that the system works satisfactorily and considerably reduces the radiation dose outside the target volume. (orig.)