Published September 1998 | Version v1
Report Open

Xenon load analysis for CANDU 6 with DUPIC fuel

Description

Xenon load for a CANDU 6 reactor with DUPIC fuel has been studies. Xenon property constants were generated by WIMS-AECL code and the xenon load was calculated by RFSP code with a 3-dimensional full core model. Validation calculation has shown that the xenon load with the xenon constants from WIMS-AECL code is predicted within 2% compared to that with the xenon constants from POWDERPUFS-V code. The xenon load has been calculated for various reactor power level changes and reactor shutdown conditions. Calculation results have shown that the xenon load of CANDU 6 loaded with the DUPIC fuel is much lower than that loaded with standard 37-element natural uranium fuel. The calculated xenon load will be used to assess the function of reactivity control devices for DUPIC core. (author). 6 tabs., 5 figs

Availability note (English)

Available from INIS in electronic form

Files

30053454.pdf

Files (375.7 kB)

Name Size Download all
md5:6a860f57fdff4da88bbed68e61442c04
375.7 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
41 p.
Report number
KAERI/TR--1132/98