Published September 1, 1986 | Version v1
Journal article

Observation of a fluxon-antifluxon collision in a Josephson transmission line

Creators

  • 1. Musashino Electrical Communications Laboratories, Nippon Telephone and Telegraph Corporation, Musashino-shi, Tokyo 180, Japan

Description

The behavior of a fluxon-antifluxon collision in a Josephson transmission line is experimentally investigated, with use of a direct measurement system for a fluxon waveform. The experiment shows an increase in propagation delay time following a collision. This result can be qualitatively explained as the effect of dissipative perturbation by using a numerical simulation and perturbation theory, where the origin of the increase in the delay time is explained in terms of a power balance equation. The effect of nonuniformity in the transmission line parameters on a collision is evaluated to account for the observed spatial distribution of delay-time increase. Analysis with a δ-function-like defect shows that there is evidence of such a defect in the experimental data

Additional details

Publishing Information

Journal Title
Phys. Rev., B: Condens. Matter
Journal Volume
34
Journal Issue
5
Series
Phys. Rev., B: Condens. Matter.
Journal Page Range
3127-3135
ISSN
0163-1829
CODEN
PRBMD