The Influence of the Axial Magnetic Field Upon-the Coaxial Plasma Gun Parameters
Creators
- 1. Plasma Physics and Nuclear Fusion Dept., Nuclear Research Center, AEA, Cairo, (Egypt)
Description
This study concerns with the influence of an applied axial magnetic field upon the electrical parameters of a coaxial plasma gun device. The experimental results are investigated with 0.5 KJ plasma gun device operated with argon gas at a pressure of 3.5 Torr. An axial time independent magnetic field with intensity of 550 G is introduced along the plasma current sheath axial region, within the annular space between the two coaxial electrodes. From the measurements of the discharge current I(t) and the voltage V(t), the electrical discharge parameters of the plasma gun device and the plasma current sheath implosion velocity are estimated, in normal mode of plasma gun operation and in the mode of presence external axial magnetic field. A comparison between these two modes is studied
Additional details
Publishing Information
- Journal Title
- Arab Journal of Nuclear Sciences and Applications
- Journal Volume
- 34
- Journal Issue
- 2
- Journal Page Range
- p. 351-356
- ISSN
- 1110-0451
- CODEN
- AJNADV
Conference
- Title
- 5. radiation physics conference (Rpc-2000)
- Dates
- 5-9 Nov 2000
- Place
- Cairo (Egypt)
INIS
- Country of Publication
- Egypt
- Country of Input or Organization
- Egypt
- INIS RN
- 33006597
- Subject category
- S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COAXIAL CABLES; CROSS SECTIONS; ELECTRIC CURRENTS; ELECTRIC DISCHARGES; ELECTRODES; LONGITUDINAL MOMENTUM; MAGNETIC FIELDS; PLASMA GUNS; PLASMA SHEATH
- Descriptors DEC
- CABLES; CONDUCTOR DEVICES; CURRENTS; ELECTRIC CABLES; ELECTRICAL EQUIPMENT; EQUIPMENT; LINEAR MOMENTUM