Published March 1977
| Version v1
Journal article
Dosimetric intercomparison of research reactors
Creators
- 1. Institut za Nuklearne Nauke Boris Kidric, Belgrade (Yugoslavia)
Description
In-pile dosimetric intercomparison measurements were made in four reactors with two types of chemical dosimeters - perfluoromethyl cyclohexane, sensitive to γ radiation only, and oxalic acid dosemeters, sensitive to both γ-rays and non-thermalized neutrons - and with Ni-foils as a threshold detector. It was established that it was possible in one single run to obtain an absorbed dose value with a consistency of better than +- 20% in an unknown reactor core. (author)
Additional details
Identifiers
Publishing Information
- Journal Title
- The International Journal of Applied Radiation and Isotopes
- Journal Volume
- 28
- Journal Issue
- 3
- Series
- Int. J. Appl. Radiat. Isot.
- Journal Page Range
- 307-311
- ISSN
- 0020-708X
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 8313431
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- ACCURACY; CHEMICAL DOSEMETERS; COMPARATIVE EVALUATIONS; GAMMA DETECTION; GAMMA DOSIMETRY; IN CORE INSTRUMENTS; NEUTRON DOSIMETRY; RADIATION DOSES; RESEARCH REACTORS; THRESHOLD DETECTORS
- Descriptors DEC
- DOSEMETERS; DOSIMETRY; MEASURING INSTRUMENTS; NEUTRON DETECTORS; RADIATION DETECTION; RADIATION DETECTORS; REACTORS; RESEARCH AND TEST REACTORS
Optional Information
- Notes
- Updated automatically by Metadata and Full-Text Enrichment Agent