SENTIRAD-An innovative personal radiation detector based on a scintillation detector and a silicon photomultiplier
Creators
- 1. Radiation Detection Department, Rotem Industries Ltd. (Israel)
- 2. Electronics and Control Laboratories, Nuclear Research Center-Negev (Israel)
Description
The alarming personal radiation detector (PRD) is a device intended for Homeland Security (HLS) applications. This portable device is designed to be worn or carried by security personnel to detect photon-emitting radioactive materials for the purpose of crime prevention. PRD is required to meet the scope of specifications defined by various HLS standards for radiation detection. It is mandatory that the device be sensitive and simultaneously small, pocket-sized, of robust mechanical design and carriable on the user's body. To serve these specialized purposes and requirements, we developed the SENTIRAD, a new radiation detector designed to meet the performance criteria established for counterterrorist applications. SENTIRAD is the first commercially available PRD based on a CsI(Tl) scintillation crystal that is optically coupled with a silicon photomultiplier (SiPM) serving as a light sensor. The rapidly developing technology of SiPM, a multipixel semiconductor photodiode that operates in Geiger mode, has been thoroughly investigated in previous studies. This paper presents the design considerations, constraints and radiological performance relating to the SENTIRAD radiation sensor.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.nima.2011.01.027Additional details
Identifiers
- DOI
- 10.1016/j.nima.2011.01.027;
- PII
- S0168-9002(11)00077-5;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 652
- Journal Issue
- 1
- Journal Page Range
- p. 41-44
- ISSN
- 0168-9002
- CODEN
- NIMAER
Conference
- Title
- 12. Symposium on radiation measurements and applications (SORMA)
- Dates
- 24-28 May 2010
- Place
- Ann Arbor, MI (United States)
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 44001766
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CRYSTALS; DESIGN; DOSE RATES; PERSONNEL MONITORING; PHOTOMULTIPLIERS; PHOTONS; RADIATION DETECTION; RADIOACTIVE MATERIALS; SCINTILLATION COUNTERS; SCINTILLATIONS; SEMICONDUCTOR MATERIALS; SENSORS; SILICON; SPECIFICATIONS
- Descriptors DEC
- BOSONS; DETECTION; ELEMENTARY PARTICLES; ELEMENTS; MASSLESS PARTICLES; MATERIALS; MEASURING INSTRUMENTS; MONITORING; PHOTOTUBES; RADIATION DETECTORS; RADIATION MONITORING; SEMIMETALS
Optional Information
- Copyright
- Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.