Monte Carlo modeling of a multi-hole collimator for high energy gamma-ray imaging
- 1. Univ. of Michigan, Ann Arbor, MI (United States). Dept. of Nuclear Engineering
Description
To develop a second generation gamma-ray camera for industrial application, various multiple-hole collimator designs that meet high-energy, high intensity and far-field imaging requirements have been studied. The collection of parallel holes each parallel to one another (parallel-hole, parallel collimator) is ineffective for imaging high energy far-field sources, whereas a collimator with parallel holes arranged in a diverging manner (parallel-hole, diverging collimator) is a good candidate for the imaging system. The response of a proposed collimator to different source conditions is modeled and presented in this work
Additional details
Publishing Information
- Journal Title
- IEEE Transactions on Nuclear Science
- Journal Volume
- 41
- Journal Issue
- 4Pt1
- Journal Page Range
- p. 898-902.
- ISSN
- 0018-9499
- CODEN
- IETNAE
Conference
- Title
- nuclear science symposium and medical imaging conference.
- Acronym
- NSS-MIC '93
- Dates
- 30 Oct - 6 Nov 1993.
- Place
- San Francisco, CA (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 26026343
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COLLIMATORS; DATA ACQUISITION; DESIGN; ENERGY RESOLUTION; GAMMA CAMERAS; MATHEMATICAL MODELS; MONTE CARLO METHOD; SPATIAL RESOLUTION
- Descriptors DEC
- CALCULATION METHODS; CAMERAS; RESOLUTION
Optional Information
- Secondary number(s)
- CONF-931051--.