Published 1999 | Version v1
Miscellaneous Open

Dosimetry of the Occupational Exposure Personnel and not exposure of the INNSZ

  • 1. Departamento de Medicina Nuclear, Instituto nacional de la nutricion Salvador Zubiran, Mexico D.F. C.P. 14100 (Mexico)

Description

In this work, was measured the equivalent dose of all the personnel of Nuclear medicine and personnel of the Institute which by its activities remain in the Department, by time determined, through thermoluminescent dosemeters and the results were that the personnel presents variable equivalent dose and it is proportional to the time and radionuclide type which use for their work. By this it is allowed to secure what the work watched with respect to radiological protection to fulfil with the International Standards standing for personnel in the Institute. (Author)

Availability note (English)

Available from INIS in electronic form

Files

32001572.pdf

Files (96.5 kB)

Name Size Download all
md5:5ef276b79fe02c792f9f0b4f007e002d
96.5 kB Preview Download

Additional details

Additional titles

Original title (Spanish)
Dosimetria del Personal Ocupacionalmente Expuesto (POE) y no expuesto del INNSZ

Publishing Information

Imprint Pagination
5 p.
Report number
INIS-MX--576

Conference

Title
2. International Conference; 12. National Congress on Solid State Dosimetry
Dates
22-24 Sep 1999
Place
Mexico City (Mexico)

INIS

Country of Publication
Mexico
Country of Input or Organization
Mexico
INIS RN
32001572
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
DOSE EQUIVALENTS; DOSE LIMITS; DOSIMETRY; ICRP; MEXICO; NUCLEAR MEDICINE; OCCUPATIONAL EXPOSURE; PERSONNEL; RADIATION PROTECTION; RADIOISOTOPES
Descriptors DEC
DEVELOPING COUNTRIES; INTERNATIONAL ORGANIZATIONS; ISOTOPES; LATIN AMERICA; MEDICINE; NORTH AMERICA; SAFETY STANDARDS; STANDARDS