Published September 2015
| Version v1
Journal article
Injection performance evaluation for SSRF storage ring
- 1. University of Chinese Academy of Sciences, Beijing (China)
- 2. Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai (China)
Description
The injection performance of the storage ring is one of the most important factors to consider at a synchrotron radiation facility, especially in the top-up mode. To evaluate the injection performance of the storage ring at the Shanghai Synchrotron Radiation Facility, we have built a bunch-by-bunch position measuring system based on an oscilloscope Input/Output Controller. Accurate assessment of energy mismatching, distribution of residual oscillation, and angle error of injection kickers can be achieved by this system. (authors)
Additional details
Identifiers
Publishing Information
- Journal Title
- Chinese Physics. C, High Energy Physics and Nuclear Physics
- Journal Volume
- 39
- Journal Issue
- 9
- Journal Page Range
- [5 p.]
- ISSN
- 1674-1137
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 49047383
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- CHARGES; DISTRIBUTION; ERRORS; EVALUATION; INJECTION; MATERIAL BALANCE; MEASURING METHODS; OSCILLATIONS; PERFORMANCE; STORAGE RINGS; SYNCHROTRON RADIATION; SYNCHROTRONS
- Descriptors DEC
- ACCELERATORS; BREMSSTRAHLUNG; CYCLIC ACCELERATORS; ELECTROMAGNETIC RADIATION; INTAKE; RADIATIONS
Optional Information
- Notes
- 12 figs., 10 refs.; http://dx.doi.org/10.1088/1674-1137/39/9/097003