Published March 21, 2002 | Version v1
Journal article

An optimization algorithm that incorporates IMRT delivery constraints

  • 1. Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS Trust, Sutton, Surrey (United Kingdom)

Description

An intensity-modulated beam optimization algorithm is presented which incorporates the delivery constraints into the optimization cycle. The optimization algorithm is based on the quasi-Newton method of iteratively solving minimization problems. The developed algorithm iteratively corrects the incident, pencil-beam-like, fluence to incorporate the delivery constraints. In the present study, the goal of the optimization algorithm is to achieve the best deliverable radiotherapy plan, subject to the constraints of the delivery technique described by a leaf-sequencing algorithm being applied concurrently. In general, if they are applied after, rather than during, the optimization cycle, the delivery constraints associated with the IMRT technique can produce local variations up to 6% in the 'optimized' dose (i.e., distribution without applied constraints) and reduce the degree of conformity, of the dose, to the PTV region. The optimization method has been applied to three IMRT delivery techniques: dynamic multileaf (DMLC), multiple-static-field (MSF) and slice-by-slice tomotherapy (NOMOS MIMiC). The beam profiles were generated for a prostate tumour with organs at risk being the rectum, bladder and femoral heads. The optimization method described was shown to generate optimum and deliverable IMRT plans for these three delivery techniques. In the case of the DMLC and MSF the optimization converged within 3-5 iterations to a mean PTV dose of 69.60±1.34 Gy and 69.71±1.34 Gy, respectively, while for NOMOS MIMiC approximately 10 iterations were needed to obtain 69.68±1.55 Gy. In addition to this, the IMRT optimization also yielded optimum fluence profiles when clustering was performed concurrently with the leaf-sequencer. An optimum between 8 and 15 clusters of equal fluence 'intensity' was shown to establish the best compromise between the number of fluence levels and the PTV dose coverage. (author)

Availability note (English)

Available online at the Web site for the journal Physics in Medicine and Biology (ISSN 1361-6560) http://www.iop.org/

Additional details

Identifiers

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
47
Journal Issue
6
Journal Page Range
p. 899-915
ISSN
0031-9155

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
33021004
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE; S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
ALGORITHMS; BLADDER; CARCINOMAS; FEMUR; OPTIMIZATION; RADIATION DOSES; RADIOTHERAPY; RECTUM
Descriptors DEC
BODY; DIGESTIVE SYSTEM; DISEASES; DOSES; GASTROINTESTINAL TRACT; INTESTINES; LARGE INTESTINE; MATHEMATICAL LOGIC; MEDICINE; NEOPLASMS; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; SKELETON; THERAPY; URINARY TRACT