Description

Magnetic field profiles measured in Extrap discharges with an imposed axial/toroidal magnetic field are analysed in the present article. In a linear device, Extrap L1, the axial current is driven by an applied electrode voltage. In the toroidal Extrap T1, the toroidal current is induced. Contributions to the current, and addition to that due to the applied voltage, may arise from radial diffusion as well as from dynamo effects like those observed in reversed field pinches. Typical magnetic field profiles are studied here in order to assess these contributions. (12 refs., 14 figs.)