Published 1977 | Version v1
Book

Measurement of the diametral evolution of a fuel element during its irradiation. The MEDINA service

  • 1. CEA Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Services des Piles
  • 2. CEA Centre d'Etudes Nucleaires de Fontenay-aux-Roses, 92 (France). Dept. d'Etudes des Combustibles a Base de Plutonium

Description

The MEDINA device has been designed for measuring the evolution of the profile of a fuel element during irradiation. The device comprises mainly a displacement unit which withdraws the fuel pin from the reactor core and passes it over electromagnetic measuring sensors. The accuracy effectively attained is about +-1μm on a fuel pin diameter of 6.5 mm. A description of the device, and the evaluation of one year of operating experience are presented

Additional details

Publishing Information

Publisher
North-Holland.
Imprint Place
Amsterdam, Netherlands
ISBN
0 7204 0572 6
Imprint Title
Measurement of irradiation-enhanced creep in nuclear materials
Journal Page Range
p. 61-64.

Conference

Title
International colloquium on measurement of irradiation enhanced creep in nuclear materials.
Dates
5 - 6 May 1976.
Place
Petten, Netherlands.

INIS

Country of Publication
European Commission (EC), Brussels (Belgium)
Country of Input or Organization
European Commission (EC), Brussels (Belgium)
INIS RN
9360742
Subject category
S42: ENGINEERING; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
DEFORMATION; FUEL ELEMENTS; IRRADIATION CAPSULES; PHYSICAL RADIATION EFFECTS
Descriptors DEC
RADIATION EFFECTS; REACTOR COMPONENTS