Published April 2008 | Version v1
Report Open

Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Kori Unit 4 Reactor Pressure Vessel

Description

This report describes a neutron fluence assessment performed for the Kori Unit 4 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. During Cycle 17 of reactor operation. an Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 4 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 17

Availability note (English)

Also available from KAERI

Files

41073007.pdf

Files (40.9 MB)

Name Size Download all
md5:5c82fd29067709be9ac10933baf8ba04
40.9 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
240 p.
Report number
KAERI/CR--297/2008

Optional Information

Notes
48 refs, 15 figs, 47 tabs