Evaluation of contrast reproduction method based on the anatomical guidance of the cerebral images reconstruction in positron emission tomography
Description
Positron emission tomography is a medical imaging modality providing in-vivo volumetric images of functional processes of the human body, which is used for the diagnosis and the following of neuro degenerative diseases. PET efficiency is however limited by its poor spatial resolution, which generates a decrease of the image local contrast and leads to an under-estimation of small cerebral structures involved in the degenerative mechanism of those diseases. This so-called partial volume effect degradation is usually corrected in a post-reconstruction processing framework through the use of anatomical information, whose spatial resolution allows a better discrimination between functional tissues. However, this kind of method has the major drawback of being very sensitive to the residual mismatches on the anatomical information processing. We developed in this thesis an alternative methodology to compensate for the degradation, by incorporating in the reconstruction process both a model of the system impulse response and an anatomically-based image prior constraint. This methodology was validated by comparison with a post-reconstruction correction strategy, using data from an anthropomorphic phantom acquisition and then we evaluated its robustness to the residual mismatches through a realistic Monte Carlo simulation corresponding to a cerebral exam. The proposed algorithm was finally applied to clinical data reconstruction. (author)
Availability note (English)
Available from INIS in electronic formFiles
40067613.pdf
Files
(17.9 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:620f51c73cbe0685a2c2f5d261b2bb61
|
17.9 MB | Preview Download |
Additional details
Additional titles
- Original title (French)
- Evaluation d'une methode de restitution de contraste basee sur le guidage anatomique de la reconstruction des images cerebrales en tomographie par emission de positons
Publishing Information
- Imprint Pagination
- 191 p.
- Report number
- FRNC-TH--7696
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 40067613
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Thesis
- Descriptors DEI
- BRAIN; IMAGE PROCESSING; IMAGES; MONTE CARLO METHOD; NERVOUS SYSTEM DISEASES; NUCLEAR MEDICINE; POSITRON COMPUTED TOMOGRAPHY
- Descriptors DEC
- BODY; CALCULATION METHODS; CENTRAL NERVOUS SYSTEM; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DISEASES; EMISSION COMPUTED TOMOGRAPHY; MEDICINE; NERVOUS SYSTEM; ORGANS; PROCESSING; TOMOGRAPHY
Optional Information
- Notes
- Also available from Bibliotheque Universitaire de Paris XI. Centre scientifique d'Orsay, Batiment, 407, 91405 - Orsay Cedex (France)