Published March 30, 1999 | Version v1
Report

Evaluation of Allowed Outage Times From a Risk and Reliability Viewpoint

  • 1. Safety Information Research Center, Nuclear Power Engineering Corporation (Japan)

Description

With respect to the safety systems during nuclear plant operation, the Safety Regulation (Technical Specification) provides allowed outage times (AOTs) for failure of one train or one component of standby systems and the surveillance test intervals (STIs) which are applied to the remaining systems during such AOTs. The effectiveness of the AOTs and STIs provided as the limiting conditions for operation (LCO) on plant safety and reliability has been evaluated with probabilistic method. The plant safety systems are designed to prevent and mitigate plant transients and accidents. To confirm this, plant behavior analysis is performed about the transients and accidents postulated as the design based events (DBE), and analyzed result is confirmed not to exceed the safety design criteria. Therefore we considered the LCO has firm connection with the criteria and it should be referred when the effectiveness of LCO is evaluated. The effectiveness of the AOTs and STIs is investigated using the system's unavailability and total probability violating the criteria for plant safety design. In addition, a certain value of the probability for the safety operation criteria was postulated to assess the effect of the AOTs and STIs

Part of:
Proceedings of the workshop on reliability data collection

Additional details

Publishing Information

Imprint Title
Proceedings of the workshop on reliability data collection
Imprint Pagination
260 p.
Journal Page Range
p. 150-166
Report number
NEA-CSNI-R--1998-10

Conference

Title
Workshop on reliability data collection
Dates
21-23 Apr 1998
Place
Budapest (Hungary)

Optional Information