Published January 10, 2000
| Version v1
Report
Restricted
SY-101 Rapid Transfer Project Low Temperature Operations Review and Recommendations to Support Lower Temperature Limits
Creators
Description
The lower temperature limit for the 241 SY-101 RAPID transfer project is currently set at 20 F Based on the analysis and recommendations in this document this limit can be lowered to 0 F. Analysis of all structures systems and components (SSCs) indicate that a reduction in operating temperature may be achieved with minor modifications to field-installed equipment. Following implementation of these changes it is recommended that the system requirements be amended to specify a temperature range for transfer or back dilute evolutions of 0 F to 100 F
Availability note (English)
Available from INIS in electronic form; Also available from OSTI as DE00801145; PURL: https://www.osti.gov/servlets/purl/801145-PBFz3C/webviewable/
Files
Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 42 p.
- Report number
- RPP--5610
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 34016746
- Subject category
- S12: MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES;
- Descriptors DEI
- EMERGENCY PLANS; LIMITING VALUES; RECOMMENDATIONS; STORAGE FACILITIES; TEMPERATURE DEPENDENCE; WASTE RETRIEVAL
- Descriptors DEC
- MANAGEMENT; WASTE MANAGEMENT
Optional Information
- Contract/Grant/Project number
- EDT-628303; AC27-99RL14047
- Funding organization
- ENVIRONMENTAL MANAGEMENT (United States)