Comparison of FLASH T2 dual-echo MRI sequence with 3D TOF MRA and SWI for evaluation of the cerebral circulation

  • 1. Department of Radiology, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou (China)

Description

Objective: To compare the FLASH T2 dual-echo MRI sequence with 3D TOF MRA and susceptibility-weighted imaging (SWI) for evaluation of the cerebral circulation. Methods: Eleven healthy volunteers underwent FLASH T2 dual-echo sequence, 3D-T0F-MRA and SWI. The visibility of the cerebral arteries and deep cerebral veins was compared. Results: Most of the cerebral arteries and deep cerebral veins were equally well seen on the dual-echo sequence in comparison with the 3D T0F MRA and SWI, respectively (P > 0.05). The 3D-T0F-MRA was significantly better than the dual-echo sequence for demonstrating the A5 segment of the anterior cerebral artery, M3-M5 segments of the middle cerebral artery and P4 segment of the posterior cerebral artery (P < 0.05). The SWI was significantly better than the dual-echo sequence for demonstrating the venae chorioidea (P < 0.05). Conclusions: FLASH T2 dual-echo can depict most cerebral arteries and deep cerebral veins. Visualization of A5, M3-M5, P4 segments of the anterior, middle and posterior cerebral arteries is better on 3D-T0F-MRA and the venae chorioidea on SWI. (authors)

Additional details

Publishing Information

Journal Title
Journal of Diagnostic Imaging and Interventional Radiology
Journal Volume
22
Journal Issue
6
Journal Page Range
p. 403-407
ISSN
1005-8001

Optional Information

Notes
4 figs., 4 tabs., 15 refs.; http://dx.doi.org/10.3969/j.issn.1005-8001.2013.06.001