Published March 1, 2007 | Version v1
Journal article

Gas multiplication process in mixtures based on Ar, CO2, CF4

  • 1. Faculty of Physics and Computer Science, AGH University of Science and Technology, Cracow (Poland)

Description

Systematic measurements of the gas multiplication factor over the range 1.0-5*105 have been made for Ar/CF4, Ar/CO2/CF4 and CO2/CF4 mixtures as a function of the applied voltage between cathode and anode at atmospheric pressure for wide range component concentrations

Additional details

Identifiers

DOI
10.1016/j.nima.2006.10.194;
PII
S0168-9002(06)02051-1;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
572
Journal Issue
1
Journal Page Range
p. 184-186
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
Frontier detectors for frontier physics
Acronym
10. Pisa meeting on advanced detectors
Dates
21-27 May 2006
Place
La Biodola, Elba (Italy)

Optional Information

Copyright
Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.