A portable measurement system for subcriticality measurements by the CF-source-driven neutron noise analysis method

Description

A portable system has been assembled that is capable of measuring the subcriticality of fissile materials using the 252CF-source-driven neutron noise analysis method. The measurement system consists of a parallel-plate ionization chamber containing 252CF, two 3He proportional counters with their associated electronics, and a small computer containing anti-aliasing filters and A/D convertors. The system Fourier analyzes the digitized data and forms the appropriate auto and cross-power spectral densities. These spectra are used to form a ratio of spectral densities, G12G13/G11G23, where 1 refers to the ionization chamber, and 2 and 3 refer to the 3He counters, from which subcriticality can be determined. The chamber and detectors are located appropriately near the fissile material. The system is capable of sampling signals at rates of up to 80 kHz and processing these data at rates of 2 kHz to form the appropriate spectra. The presently configured system is a two-channel system, hence the measurement of G12, G13, and G23 must be done sequentially before the ratio of spectral densities is obtained. Future improvements of the system will allow simultaneous measurement of all spectra and will further reduce size, thereby enhancing portability. This measurement system can provide reliable, cost effective, and convenient determination of the subcriticality of a wide variety of fissile materials and moderators

Availability note (English)

Available from NTIS, PC A02/MF A01; 1 as DE87008592.

Files

19019039.pdf

Files (149.8 kB)

Name Size Download all
md5:d9dbdbe18e2d499e681e6c0bdfee7cbe
149.8 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
6 p.
Report number
CONF-871005--1

Conference

Title
Nuclear power systems symposium.
Dates
21-23 Oct 1987.
Place
San Francisco, CA (USA).

Optional Information

Notes
Portions of this document are illegible in microfiche products.