Response of a neutron monitor area with TLDs pairs

  • 1. Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)
  • 2. Universidad Politecnica de Madrid, Departamento de Ingenieria Nuclear, Jose Gutierrez Abascal 2, E-28006 Madrid (Spain)

Description

The response of a passive neutron monitor area has been calculated using the Monte Carlo code MCNP5. The response was the amount of n(6Li, T)α reactions occurring in a TLD-600 located at the center of a cylindrical polyethylene moderator. Fluence, (n, a) and H*(10) responses were calculated for 47 monoenergetic neutron sources. The H*(10) relative response was compared with responses of commercially available neutron monitors being alike. Due to 6Li cross section (n, α) reactions are mainly produced by thermal neutrons, however TLD-600 is sensitive to gamma-rays; to eliminate the signal due to photons monitor area was built to hold 2 pairs of TLD-600 and 2 pairs of TLD-700, thus from the difference between TLD-600 and TLD-700 readouts the net signal due to neutrons is obtained. The monitor area was calibrated at the Universidad Politecnica de Madrid using a 241AmBe neutron source; net TLD readout was compared with the H*(10) measured with a Bert hold Lb-6411. Performance of the neutron monitor area was determined through two independent experiments, in both cases the H*(10) was statistically equal to H*(10) measured with a Bert hold Lb-6411. Neutron monitor area with TLDs pairs can be used in working areas with intense, mixed and pulsed radiation fields. (Author)

Files

43009443.pdf

Files (750.2 kB)

Name Size Download all
md5:ff58a39134bdfbf2a454d6a37cf29167
750.2 kB Preview Download

Additional details

Publishing Information

Publisher
Sociedad Mexicana de Irradiacion y Dosimetria
Imprint Place
Mexico D. F. (Mexico)
Imprint Pagination
[10 p.]
Report number
INIS-MX--2640

Conference

Title
12. International Symposium; 22. National Congress on Solid State Dosimetry
Original Conference Title
12. Conferencia Internacional. 22. Congreso Nacional sobre Dosimetria de Estado Solido
Dates
5-9 Sep 2011
Place
Mexico D. F. (Mexico)