Published January 1, 2007 | Version v1
Report

Tuning the narrow-band beam position monitor sampling clock to remove the aliasing errors in APS storage ring orbit measurements

Description

The Advanced Photon Source storage ring employs a real-time orbit correction system to reduce orbit motion up to 50 Hz. This system uses up to 142 narrow-band rf beam position monitors (Nbbpms) in a correction algorithm by sampling at a frequency of 1.53 kHz. Several Nbbpms exhibit aliasing errors in orbit measurements, rendering these Nbbpms unusable in real-time orbit feedback. The aliasing errors are caused by beating effects of the internal sampling clocks with various other processing clocks residing within the BPM electronics. A programmable external clock has been employed to move the aliasing errors out of the active frequency band of the real-time feedback system (RTFB) and rms beam motion calculation. This paper discusses the process of tuning and provides test results.

Availability note (English)

Available from IEEE Xplore Digital Library

Additional details

Identifiers

Publishing Information

Imprint Pagination
3 p.
Report number
ANL/ASD/CP--59537

Conference

Title
Particle Accelerator Conference
Acronym
PAC07
Dates
25-29 Jun 2007
Place
Albuquerque, NM (United States)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
42061012
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ACCELERATORS; ADVANCED PHOTON SOURCE; ALGORITHMS; BEAM POSITION; FEEDBACK; MONITORS; PROCESSING; SAMPLING; STORAGE RINGS; TUNING
Descriptors DEC
MATHEMATICAL LOGIC; MEASURING INSTRUMENTS; RADIATION SOURCES; STORAGE RINGS; SYNCHROTRON RADIATION SOURCES

Optional Information

Contract/Grant/Project number
AC02-06CH11357
Notes
Proc., ISBN 978-1-4244-0916-7, pp. 4402-4404; doi 10.1109/PAC.2007.4440019
Funding organization
USDOE Office of Science (United States)