Published February 1992 | Version v1
Journal article

Investigation of the Extracted H- current in a continuously pulsed-volume negative-ion source

  • 1. FOM-Institute for Atomic and Molecular Physics, Amsterdam (Netherlands)
  • 2. University Coll., Dublin (Ireland). Dept. of Physics

Description

We have observed a significant increase in average extracted negative-ion current (I-) when pulsing the discharge current of a small, high-power density volume negative-ion source at low pressures. Compared to a DC-operated discharge, (I-) is increased by 35% at a pressure of 0.38 Pa. This result is explained with a simple model which shows that the enhancement of (I-) at low pressures can be attributed to an increased production of negative ions through dissociative attachment, as a result of the colder electrons in the postdischarge. The temporal behaviour of the extracted negative-ion current in this small, high-power density source is markedly different than the negative-ion current of a larger low-power density source

Additional details

Publishing Information

Journal Title
Europhysics Letters
Journal Volume
17
Journal Issue
6
Series
Europhys. Lett.
Journal Page Range
503-508
CODEN
EULEE

INIS

Country of Publication
France
Country of Input or Organization
France
INIS RN
23056310
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Descriptors DEI
ELECTRIC DISCHARGES; HYDROGEN IONS 1 MINUS; ION SOURCES; MEDIUM VACUUM; PLASMA; PULSES
Descriptors DEC
ANIONS; CHARGED PARTICLES; HYDROGEN IONS; IONS