Published 2001
| Version v1
Miscellaneous
Reflooding Experimental On Beta Test Loop : The Characterisation And Preliminary Experiment
- 1. Center for Development of Nuclear Safety Technology, National Atomic Energy Agency (Indonesia)
Description
The characterisation and preliminary experiment of reflooding had been conducted. The characteristics of main system and component had been identified completely. From these characteristics the experiment condition was set up : heated rod voltage was 20 volt, frequency,of pump was 19 Hz, flow rate was 1 m3/h. The first of experiment did not show the phenomena of rewetting. Possibly because the heated rod temperature was too low. For the second experiment, the voltage of heated rod was increased to 22 Volt and the flow rate was decreased. The result was that the nucleation boiling on the surfaced of heated rod, was observed during the water re flooded the test section
Additional details
Additional titles
- Original title (Indonesian)
- Eksperimen reflooding Pada Untai Uji Beta: Karakterisasi Dan Eksperimen Awal
Publishing Information
- Publisher
- Center for Development of Nuclear Safety Technology, National Atomic Energy Agency
- Imprint Place
- Serpong (Indonesia)
- Imprint Title
- The Sixth of Scientific Presentation Nuclear Safety Technology
- Imprint Pagination
- 246 p.
- Journal Page Range
- p. 106-118
- ISSN
- 1410-0533
- Report number
- INIS-ID--028
Conference
- Title
- 6. Conference of Nuclear Safety Technology
- Original Conference Title
- Teknologi Keselamatan Nuklir ke VI
- Dates
- 29 Mar 2001
- Place
- Serpong (Indonesia)
INIS
- Country of Publication
- Indonesia
- Country of Input or Organization
- Indonesia
- INIS RN
- 35097817
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- ACCIDENTS; FLOOD CONTROL; FLOW RATE; REACTOR CORES; SAFETY ANALYSIS; THERMOELECTRIC HEATERS
- Descriptors DEC
- CONTROL; DIRECT ENERGY CONVERTERS; HEATERS; REACTOR COMPONENTS
Optional Information
- Notes
- 2 refs; 6 tabs; 6 figs