Respiratory motion correction for PET oncology applications using affine transformation of list mode data
- 1. INSERM U650, Laboratoire du Traitement de l'information medicale (LaTIM), Universite de Bretagne occidentale, Brest (France)
- 2. Department of Instrumentation and Analytical Science, UMIST, Manchester (United Kingdom)
Description
Respiratory motion is a source of artefacts and reduced image quality in PET. Proposed methodology for correction of respiratory effects involves the use of gated frames, which are however of low signal-to-noise ratio. Therefore a method accounting for respiratory motion effects without affecting the statistical quality of the reconstructed images is necessary. We have implemented an affine transformation of list mode data for the correction of respiratory motion over the thorax. The study was performed using datasets of the NCAT phantom at different points throughout the respiratory cycle. List mode data based PET simulated frames were produced by combining the NCAT datasets with a Monte Carlo simulation. Transformation parameters accounting for respiratory motion were estimated according to an affine registration and were subsequently applied on the original list mode data. The corrected and uncorrected list mode datasets were subsequently reconstructed using the one-pass list mode EM (OPL-EM) algorithm. Comparison of corrected and uncorrected respiratory motion average frames suggests that an affine transformation in the list mode data prior to reconstruction can produce significant improvements in accounting for respiratory motion artefacts in the lungs and heart. However, the application of a common set of transformation parameters across the imaging field of view does not significantly correct the respiratory effects on organs such as the stomach, liver or spleen
Additional details
Identifiers
- DOI
- 10.1088/0031-9155/52/1/009;
- PII
- S0031-9155(07)30237-6;
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 52
- Journal Issue
- 1
- Journal Page Range
- p. 121-140
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 38069521
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALGORITHMS; CHEST; COMPUTERIZED SIMULATION; CORRECTIONS; HEART; IMAGES; LIVER; LUNGS; MONTE CARLO METHOD; PHANTOMS; SIGNAL-TO-NOISE RATIO; SPLEEN; STOMACH
- Descriptors DEC
- BODY; CALCULATION METHODS; CARDIOVASCULAR SYSTEM; DIGESTIVE SYSTEM; DIMENSIONLESS NUMBERS; GASTROINTESTINAL TRACT; GLANDS; MATHEMATICAL LOGIC; MOCKUP; ORGANS; RESPIRATORY SYSTEM; SIMULATION; STRUCTURAL MODELS