Published March 1988 | Version v1
Journal article

Aseismatic supporting structures

  • 1. Hitachi Ltd., Tokyo (Japan)

Description

As one of the large subjects for putting FBRs to practical use, the increase of the economical efficiency is pointed out, and for this purpose, the reduction of the construction cost by the simplification of system and the rationalization of equipment structures becomes an important target of development. The operational condition of FBR cooling system is high temperature above 500 deg C at core exit, and low pressure below 6 kg-cm2g. Consequently, the effect of earthquake load in the structural strength design is relatively large, accordingly the reduction of earthquake load is effective from the viewpoint of structural rationalization. Hitachi Ltd. considered that earthquake isolation is an effective means to reduce earthquake response, and has examined the effect and feasibility of introducing earthquake isolation into FBR plants for three years from 1984. In this study, the mechanical characteristics and endurance of the system suitable to the earthquake isolation of FBRs were examined, the effect of reducing earthquake response by earthquake isolation was grasped, and the effect of plant rationalization brought about by the reduction of earthquake input was examined. The summary of these studies is shown. (Kako, I.)

Additional details

Publishing Information

Journal Title
Genshiryoku Kogyo
Journal Volume
34
Journal Issue
3
Series
Genshiryoku Kogyo.
Journal Page Range
22-25
ISSN
0433-4035
CODEN