On-line estimations of delivered radiation doses in three-dimensional conformal radiotherapy treatments of carcinoma uterine cervix patients in linear accelerator
Creators
- 1. Department of Radiotherapy and Oncology, Kasturba Medical College Hospital, Mangalore (India)
- 2. Department of Radiation Oncology, Manipal Hospital, Bengaluru (India)
- 3. Department of Medical Radiation Physics, School of Allied Health Sciences, Manipal University, Manipal (India)
- 4. Department of Radiological Physics, SMS Medical College, Jaipur (India)
Description
Transmission of radiation fluence through patient's body has a correlation to the planned target dose. A method to estimate the delivered dose to target volumes was standardized using a beam level 0.6 cc ionization chamber (IC) positioned at electronic portal imaging device (EPID) plane from the measured transit signal (St) in patients with cancer of uterine cervix treated with three-dimensional conformal radiotherapy (3DCRT). The IC with buildup cap was mounted on linear accelerator EPID frame with fixed source to chamber distance of 146.3 cm, using a locally fabricated mount. S t s were obtained for different water phantom thicknesses and radiation field sizes which were then used to generate a calibration table against calculated midplane doses at isocenter (D iso,TPS), derived from the treatment planning system. A code was developed using MATLAB software which was used to estimate the in vivo dose at isocenter (D iso,Transit) from the measured St s. A locally fabricated pelvic phantom validated the estimations of D iso,Transit before implementing this method on actual patients. On-line dose estimations were made (3 times during treatment for each patient) in 24 patients. The D iso,Transit agreement with D iso,TPS in phantom was within 1.7% and the mean percentage deviation with standard deviation is -1.37% ±2.03% (n = 72) observed in patients. Estimated in vivo dose at isocenter with this method provides a good agreement with planned ones which can be implemented as part of quality assurance in pelvic sites treated with simple techniques, for example, 3DCRT where there is a need for documentation of planned dose delivery. (author)
Additional details
Publishing Information
- Journal Title
- Journal of Medical Physics
- Journal Volume
- 41
- Journal Issue
- 4
- Journal Page Range
- p. 224-233
- ISSN
- 0971-6203
INIS
- Country of Publication
- India
- Country of Input or Organization
- India
- INIS RN
- 51080944
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CARCINOMAS; CLINICAL TRIALS; COMPUTERIZED TOMOGRAPHY; EFFECTIVE RADIATION DOSES; IMAGE PROCESSING; THREE-DIMENSIONAL CALCULATIONS; UROGENITAL SYSTEM DISEASES
- Descriptors DEC
- DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; NEOPLASMS; PROCESSING; RADIATION DOSES; TESTING; TOMOGRAPHY