Published September 1962
| Version v1
Report
Open
Void Measurement by the (γ, n) Reaction
Description
It is proposed to use the (γ, n) reaction for the measurement of the integrated void volume fraction in two phase flow of D2O inside a duct. This method is applicable to different channel geometries, and it is shown to be insensitive to the pattern of void distribution over the cross-sectional area of the channels The method has been tested on mock-ups of voids in a round duct of 6 mm inside diameter. About 40 m.c. 24Na was used as a source of gamma-rays. The test results show that the maximum measured error in this arrangement is less than 2.5 % (net void) for a range of 2.7 % to 44.44 % actual void volume fractions
Availability note (English)
Available from INIS in electronic formFiles
38092889.pdf
Files
(417.3 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:6f89786f5b6f193d4ff48dce8972b541
|
417.3 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 24 p.
- Report number
- AE--83
INIS
- Country of Publication
- Sweden
- Country of Input or Organization
- Sweden
- INIS RN
- 38092889
- Subject category
- S42: ENGINEERING; S73: NUCLEAR PHYSICS AND RADIATION PHYSICS;
- Descriptors DEI
- DUCTS; HEAVY WATER; PHOTONUCLEAR REACTIONS; TWO-PHASE FLOW; VOID FRACTION
- Descriptors DEC
- DEUTERIUM COMPOUNDS; FLUID FLOW; HYDROGEN COMPOUNDS; NUCLEAR REACTIONS; OXYGEN COMPOUNDS; WATER
Optional Information
- Notes
- 11 refs., 2 figs.