Published September 1962 | Version v1
Report Open

Void Measurement by the (γ, n) Reaction

Description

It is proposed to use the (γ, n) reaction for the measurement of the integrated void volume fraction in two phase flow of D2O inside a duct. This method is applicable to different channel geometries, and it is shown to be insensitive to the pattern of void distribution over the cross-sectional area of the channels The method has been tested on mock-ups of voids in a round duct of 6 mm inside diameter. About 40 m.c. 24Na was used as a source of gamma-rays. The test results show that the maximum measured error in this arrangement is less than 2.5 % (net void) for a range of 2.7 % to 44.44 % actual void volume fractions

Availability note (English)

Available from INIS in electronic form

Files

38092889.pdf

Files (417.3 kB)

Name Size Download all
md5:6f89786f5b6f193d4ff48dce8972b541
417.3 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
24 p.
Report number
AE--83

INIS

Country of Publication
Sweden
Country of Input or Organization
Sweden
INIS RN
38092889
Subject category
S42: ENGINEERING; S73: NUCLEAR PHYSICS AND RADIATION PHYSICS;
Descriptors DEI
DUCTS; HEAVY WATER; PHOTONUCLEAR REACTIONS; TWO-PHASE FLOW; VOID FRACTION
Descriptors DEC
DEUTERIUM COMPOUNDS; FLUID FLOW; HYDROGEN COMPOUNDS; NUCLEAR REACTIONS; OXYGEN COMPOUNDS; WATER

Optional Information

Notes
11 refs., 2 figs.