Lorentz force electrical impedance tomography using magnetic field measurements
Creators
- 1. Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara (Turkey)
Description
In this study, magnetic field measurement technique is investigated to image the electrical conductivity properties of biological tissues using Lorentz forces. This technique is based on electrical current induction using ultrasound together with an applied static magnetic field. The magnetic field intensity generated due to induced currents is measured using two coil configurations, namely, a rectangular loop coil and a novel xy coil pair. A time-varying voltage is picked-up and recorded while the acoustic wave propagates along its path. The forward problem of this imaging modality is defined as calculation of the pick-up voltages due to a given acoustic excitation and known body properties. Firstly, the feasibility of the proposed technique is investigated analytically. The basic field equations governing the behaviour of time-varying electromagnetic fields are presented. Secondly, the general formulation of the partial differential equations for the scalar and magnetic vector potentials are derived. To investigate the feasibility of this technique, numerical studies are conducted using a finite element method based software. To sense the pick-up voltages a novel coil configuration (xy coil pairs) is proposed. Two-dimensional numerical geometry with a 16-element linear phased array (LPA) ultrasonic transducer (1 MHz) and a conductive body (breast fat) with five tumorous tissues is modeled. The static magnetic field is assumed to be 4 Tesla. To understand the performance of the imaging system, the sensitivity matrix is analyzed. The sensitivity matrix is obtained for two different locations of LPA transducer with eleven steering angles from to at intervals of . The characteristics of the imaging system are shown with the singular value decomposition (SVD) of the sensitivity matrix. The images are reconstructed with the truncated SVD algorithm. The signal-to-noise ratio in measurements is assumed 80 dB. Simulation studies based on the sensitivity matrix analysis reveal that perturbations with mm size can be detected up to a 3.5 cm depth. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/0031-9155/61/16/5887Additional details
Identifiers
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 61
- Journal Issue
- 16
- Journal Page Range
- p. 5887-5905
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 51021168
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ALGORITHMS; ANIMAL TISSUES; COMPUTER CODES; ELECTRIC CONDUCTIVITY; ELECTRIC CURRENTS; ELECTRIC POTENTIAL; ELECTROMAGNETIC FIELDS; FIELD EQUATIONS; FINITE ELEMENT METHOD; IMAGES; IMPEDANCE; MAMMARY GLANDS; NUMERICAL ANALYSIS; PARTIAL DIFFERENTIAL EQUATIONS; PERTURBATION THEORY; SENSITIVITY; SIGNAL-TO-NOISE RATIO; STATIC MAGNETIC FIELDS; TOMOGRAPHY; TRANSDUCERS
- Descriptors DEC
- BODY; CALCULATION METHODS; CURRENTS; DIAGNOSTIC TECHNIQUES; DIFFERENTIAL EQUATIONS; DIMENSIONLESS NUMBERS; ELECTRICAL PROPERTIES; EQUATIONS; GLANDS; MAGNETIC FIELDS; MATHEMATICAL LOGIC; MATHEMATICAL SOLUTIONS; MATHEMATICS; NUMERICAL SOLUTION; ORGANS; PHYSICAL PROPERTIES