Published June 2013 | Version v1
Journal article

A quality control model that uses PTV-rectal distances to predict the lowest achievable rectum dose, improves IMRT planning for patients with prostate cancer

  • 1. Department of Radiation Oncology, Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands)
  • 2. Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore (United States)

Description

Background and purpose: To predict the lowest achievable rectum D35 for quality assurance of IMRT plans of prostate cancer patients. Materials and methods: For each of 24 patients from a database of 47 previously treated patients, the anatomy was compared to the anatomies of the other 46 to predict the minimal achievable rectum D35. The 24 patients were then replanned to obtain maximally reduced rectum D35. Next, the newly derived plans were added to the database to replace the original clinical plans, and new predictions of the lowest achievable rectum D35 were made. Results: After replanning, the rectum D35 reduced by 9.3 Gy ± 6.1 (average ± 1 SD; p < 0.001) compared to the original plan. The first predictions of the rectum D35 were 4.8 Gy ± 4.2 (average ± 1 SD; p < 0.001) too high when evaluated with the new plans. After updating the database, the replanned and newly predicted rectum D35 agreed within 0.1 Gy ± 2.8 (average ± 1 SD; p = 0.89). The doses to the bladder, anus and femoral heads did not increase compared to the original plans. Conclusions: For individual prostate patients, the lowest achievable rectum D35 in IMRT planning can be accurately predicted from dose distributions of previously treated patients by quantitative comparison of patient anatomies. These predictions can be used to quantitatively assess the quality of IMRT plans

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radonc.2013.05.032

Additional details

Identifiers

DOI
10.1016/j.radonc.2013.05.032;
PII
S0167-8140(13)00273-9;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
107
Journal Issue
3
Journal Page Range
p. 352-357
ISSN
0167-8140
CODEN
RAONDT

INIS

Country of Publication
Ireland
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
45088235
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ANATOMY; NEOPLASMS; PATIENTS; PROSTATE; QUALITY ASSURANCE; RADIATION DOSE DISTRIBUTIONS; RADIOTHERAPY; RECTUM
Descriptors DEC
BIOLOGY; BODY; DIGESTIVE SYSTEM; DISEASES; GASTROINTESTINAL TRACT; GLANDS; INTESTINES; LARGE INTESTINE; MALE GENITALS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.