Published September 1987 | Version v1
Report

Turbine protection system evaluation: Final report

Description

Databases from operating nuclear power plants indicate that malfunction of the turbine protection system (TPS) initiates a significant number of spurious plant transients. Most such transients result in reactor shutdowns, thereby reducing plant availability and adversely affecting the thermal cycle life of plant pressure boundary components. Improved nuclear power plant availability can result from reducing false-alarm emergency plant shutdowns initiated by faulty turbine protection systems. Analyses suggest that potentially corrective retrofit actions can provide significant cost-benefits while helping utilities achieve scram reduction goals. This report determines the magnitude and cost impact of lost plant availability due to TPS malfunctions, identifies the root causes of the equipment malfunctions, and determines appropriate corrective actions and develops methods of evaluating their cost-effectiveness and assessing the potential effects on plant licensing

Availability note (English)

Research Reports Center, Box 50490, Palo Alto, CA 94303.

Additional details

Publishing Information

Imprint Pagination
177 p.
Report number
EPRI-NP--5416

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
19013596
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
AVAILABILITY; EQUIPMENT PROTECTION DEVICES; EVALUATION; NUCLEAR POWER PLANTS; REACTOR INSTRUMENTATION; REACTOR PROTECTION SYSTEMS; REACTOR SHUTDOWN; RELIABILITY; STEAM TURBINES; TRANSIENTS
Descriptors DEC
NUCLEAR FACILITIES; POWER PLANTS; SHUTDOWN; THERMAL POWER PLANTS; TURBINES