Published November 1986
| Version v1
Journal article
Inherent/passive safety for fusion
Description
The concept of inherent or passive safety for fusion energy is explored, defined, and partially quantified. Four levels of safety assurance are defined, which range from true inherent safety to passive safety to protection via active engineered safeguard systems. Fusion has the clear potential for achieving inherent or passive safety, which should be an objective of fusion research and design. Proper material choice might lead to both inherent safety and high mass power density, improving both safety and economics. When inherent safety is accomplished, fusion will be well on the way to achieving its ultimate potential and to be truly different and superior
Additional details
Publishing Information
- Journal Title
- Fusion Technol.
- Journal Volume
- 10
- Journal Issue
- 3
- Series
- Fusion Technol.
- Journal Page Range
- 1191-1196
- ISSN
- 0748-1896
- CODEN
- FUSTE
Conference
- Title
- 7. topical meeting on the technology of fusion energy.
- Dates
- 15-19 Jun 1986.
- Place
- Reno, NV (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 18041143
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ECONOMICS; POWER DENSITY; RADIATION PROTECTION; REACTOR SAFETY; RESEARCH PROGRAMS; SAFEGUARDS; SAFETY ENGINEERING; THERMONUCLEAR REACTOR MATERIAL; THERMONUCLEAR REACTORS
- Descriptors DEC
- MATERIALS; SAFETY
Optional Information
- Secondary number(s)
- CONF-860652--.