Published September 1995
| Version v1
Report
Status report on HIRFL ECR2 ion source
- 1. Academia Sinica, Lanzhou, GS (China). Inst. of Modern Physics
Description
The parameters and performance of HIRFL ECR2 are presented. Some problems met during the source tuning are mentioned. A better result was obtained by using a thin tube of Zr to cover the inner wall of the plasma cavity. A plan for source test in the near future is described briefly. (author)
Additional details
Publishing Information
- Imprint Title
- Proceedings of the 12th international workshop on ECR ion sources
- Imprint Pagination
- 363 p.
- Journal Page Range
- p. 235-236.
- Report number
- INS-J--182
Conference
- Title
- 12. international workshop on ECR ion sources; 24. INS symposium on ECR ion sources and their applications.
- Dates
- 25-27 Apr 1995.
- Place
- Wako, Saitama (Japan).
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 27052389
- Subject category
- S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ELECTRON CYCLOTRON-RESONANCE; GASES; ION SOURCES; MAGNETIC FIELDS; MICROWAVE RADIATION; MULTICHARGED IONS; PERFORMANCE; PLASMA HEATING; ZIRCONIUM
- Descriptors DEC
- CHARGED PARTICLES; CYCLOTRON RESONANCE; ELECTROMAGNETIC RADIATION; ELEMENTS; FLUIDS; HEATING; IONS; METALS; RADIATIONS; RESONANCE; TRANSITION ELEMENTS