Labelling of biological structures with technetium 99 m

Description

The labelling of red blood cells (RBC) with technetium 99m (99m Tc) depends on several factors, as the stannous ion (Sn++) concentration, the time and temperature of incubation, the anticoagulant utilized, the presence of plasma proteins (PP) and others. Although the blinding of 99m Tc with hemoglobin and PP are similar, they appear to have specific characteristics as demonstrated by precipitation with alcohol, acetone, trichloroacetic acid, hydrochloric acid and mercury chloride. The bacterial cultures labeled with Technetium-99m, at optimal Sn++ ion concentration, presents a large stability and their viability is not altered by this treatment. The electrophoretic mobility, the hydrophobicity, the cationized ferritin distribution and the adherence to human buccal epithelial cells are not modified either. The possibility of labelling with 99m Tc of planaria and cercariae of Schistossoma mansoni evaluative cycle increases the utilization of this radionuclide to an experimental level. The results described with the labelling of these biological structures with 99m Tc demonstrated that stable labeled and viable operations are obtained. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

25009883.pdf

Files (4.0 MB)

Name Size Download all
md5:714adfa9e341f5a6085e8544dc367578
4.0 MB Preview Download

Additional details

Additional titles

Original title (Portuguese)
Marcacao de estruturas biologicas com tecnecio

Publishing Information

Imprint Pagination
148 p.
Report number