Published 1998 | Version v1
Miscellaneous Open

Numerical modeling of the radiation field in a calibration facility using Monte Carlo techniques

  • 1. Ciemat, Madrid, (Spain)

Description

Different ESG4 based Monte Carlo codes have been used to calculate the spatial distribution of some radiological quantities (air kerma and air absorbed dose) due to the presence of radiation sources in a specific workplace. Such distribution is of great interest in the case of the inhomogeneous fields produced by collimated beams and depends critically on the source distribution and its detailed geometry. From microdosimetric considerations, a new AUSGAB subroutine has been developed, permitting to obtain results which cannot be measured experimentally, such as the direct and scattered contributions to air kerma and air absorbed dose. (author)

Files

30031603.pdf

Files (74.4 kB)

Name Size Download all
md5:db9808197866a5959d48a0fb21b78cf0
74.4 kB Preview Download
Part of:
Proceedings of the IRPA regional symposium on radiation protection in neighbouring countries of Central Europe

Additional details

Publishing Information

Imprint Title
Proceedings of the IRPA regional symposium on radiation protection in neighbouring countries of Central Europe
Imprint Pagination
671 p.
Journal Page Range
p. 525-527
Report number
INIS-CZ--0021

Conference

Title
IRPA regional symposium on radiation protection in neighbouring countries of Central Europe
Dates
8-12 Sep 1997
Place
Prague (Czech Republic)

Optional Information

Notes
3 figs., 4 refs.