Published 1984 | Version v1
Book

The use of thin layer activation techniques for studying corrosion in economiser piping

  • 1. Risley Nuclear Power development Laboratory (UK)

Description

The TLA technique has been utilised to study the relative corrosion resistance of various candidate economizer and restrictor tube materials for second generation AGR steam plant. A study of potentially susceptible areas of return bends in a serpentine platen geometry relevant to the economizer design has not indicated the occurrence of erosion-corrosion under the conditions studied. It is proposed to extend the studies to lower temperatures. 2 tables, 8 references and 12 figures are given

Part of:
Corrosion erosion of steels in high temperature water and wet steam

Additional details

Additional titles

Original title (no language)
Corrosion-erosion des aciers dans l'eau et la vapeur humide.

Publishing Information

Publisher
Electricite de France.
Imprint Place
Paris (France)
Imprint Title
Corrosion erosion of steels in high temperature water and wet steam
Imprint Pagination
572 p.
Journal Page Range
no. 20 p. 1-23.

Conference

Title
erosion of steels in high temperature water and wet steam.
Acronym
EDF specialists meeting on the corrosion
Dates
12 May 1982.
Place
Ecuelles (France).

Optional Information

Notes
Imprint:Corrosion-erosion des aciers dans l'eau et la vapeur humide.;Recueil des communications.