Electrical breakdown across a vacuum/plastic interface in the presence of applied or self-generated magnetic fields, B< or =3.5 T, was investigated. The E x B drift of charged particles near the interface in these experiments was away from the insulator surface. The self-magnetic field effects on a plastic vacuum insulator flashover were examined with inductive loads, particle beam loads, and imploding plasma loads. Average breakdown electric fields of up to 38 MV/m were observed. Power densities of 100 TW/m2 were passed through acrylic-vacuum interfaces. The flashover electric fields were improved over the B = 0 fields from previous experiments by factors of 7.1, 5.0, and 1.8 for the -450, 00, and +450 insulators, respectively