The thermoluminescence response of doped SiO2 optical fibres subjected to photon and electron irradiations
- 1. Department of Physics, Universiti Teknologi Malaysia, 81310 Skudai, Johor Darul, Takzim (Malaysia)
- 2. Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom)
- 3. Surrey Ion Beam Centre, University of Surrey, Guildford GU2 7XH (United Kingdom)
Description
Modern linear accelerators, the predominant teletherapy machine in major radiotherapy centres worldwide, provide multiple electron and photon beam energies. To obtain reasonable treatment times, intense electron beam currents are achievable. In association with this capability, there is considerable demand to validate patient dose using systems of dosimetry offering characteristics that include good spatial resolution, high precision and accuracy. Present interest is in the thermoluminescence response and dosimetric utility of commercially available doped optical fibres. The important parameter for obtaining the highest TL yield during this study is to know the dopant concentration of the SiO2 fibre because during the production of the optical fibres, the dopants tend to diffuse. To achieve this aim, proton-induced X-ray emission (PIXE), which has no depth resolution but can unambiguously identify elements and analyse for trace elements with detection limits approaching μg/g, was used. For Al-doped fibres, the dopant concentration in the range 0.98-2.93 mol% have been estimated, with equivalent range for Ge-doped fibres being 0.53-0.71 mol%. In making central-axis irradiation measurements a solid waterTM phantom was used. For 6-MV photons and electron energies in the range 6, 9 and 12 MeV, a source to surface distance of 100 cm was used, with a dose rate of 400 cGy/min for photons and electrons. The TL measurements show a linear dose-response over the delivered range of absorbed dose from 1 to 4 Gy. Fading was found to be minimal, less than 10% over five days subsequent to irradiation. The minimum detectable dose for 6-MV photons was found to be 4, 30 and 900 μGy for TLD-100 chips, Ge- and Al-doped fibres, respectively. For 6-, 9- and 12-MeV electron energies, the minimum detectable dose were in the range 3-5, 30-50 and 800-1400 μGy for TLD-100 chip, Ge-doped and Al-doped fibres, respectively
Availability note (English)
Available from http://dx.doi.org/10.1016/j.apradiso.2008.06.030Additional details
Identifiers
- DOI
- 10.1016/j.apradiso.2008.06.030;
- PII
- S0969-8043(08)00328-X;
Publishing Information
- Journal Title
- Applied Radiation and Isotopes
- Journal Volume
- 67
- Journal Issue
- 3
- Journal Page Range
- p. 423-427
- ISSN
- 0969-8043
- CODEN
- ARISEF
Conference
- Title
- 1. international conference on biomedical applications of high energy ion beams
- Dates
- 30 Jul - 2 Aug 2007
- Place
- Surrey (United Kingdom)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 40045601
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DOPED MATERIALS; ELECTRON BEAMS; IRRADIATION; LINEAR ACCELERATORS; MEV RANGE 01-10; MEV RANGE 10-100; OPTICAL FIBERS; PHANTOMS; PHOTON BEAMS; PHOTONS; PIXE ANALYSIS; PROTON BEAMS; PROTONS; RADIATION DOSES; RADIOTHERAPY; RUTHERFORD BACKSCATTERING SPECTROSCOPY; SILICON OXIDES; SPATIAL RESOLUTION; THERMOLUMINESCENCE; X RADIATION
- Descriptors DEC
- ACCELERATORS; BARYONS; BEAMS; BOSONS; CHALCOGENIDES; CHEMICAL ANALYSIS; DOSES; ELECTROMAGNETIC RADIATION; ELEMENTARY PARTICLES; EMISSION; ENERGY RANGE; FERMIONS; FIBERS; HADRONS; IONIZING RADIATIONS; LEPTON BEAMS; LUMINESCENCE; MASSLESS PARTICLES; MATERIALS; MEDICINE; MEV RANGE; MOCKUP; NONDESTRUCTIVE ANALYSIS; NUCLEAR MEDICINE; NUCLEON BEAMS; NUCLEONS; OXIDES; OXYGEN COMPOUNDS; PARTICLE BEAMS; PHOTON EMISSION; RADIATIONS; RADIOLOGY; RESOLUTION; SILICON COMPOUNDS; SPECTROSCOPY; STRUCTURAL MODELS; THERAPY; X-RAY EMISSION ANALYSIS
Optional Information
- Copyright
- Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.