Published May 1992 | Version v1
Journal article

Reliability analysis of the system for continuous cleanup of WWER-440 nuclear power plant primary circuit water

  • 1. Vyzkumny Ustav Chemickych Zarizeni, Brno (Czechoslovakia)

Description

A new potential for the practical use of the CAT-PREP-KITT computer code in reliability analysis of nuclear power plant components is outlined. The procedure is demonstrated on the primary circuit water continuous cleanup system of a WWER-400 nuclear power plant. Variant calculations were performed for the two loops, TC 10 and TC 50; the loops were found equivalent with respect to reliability. The calculated reliability characteristics of the TC 10 loop indicate that with an 80% probability at least one loop failure can be expected within a year of operation. One failure of the facility (which need not imply failure of the loop) can be expected roughly in 8 months of operation. The expected number of failures is low but any failure is significant with respect to loop failure. (Z.S.). 5 tabs., 4 figs., 8 refs

Additional details

Additional titles

Original title (Czech)
Analyza spolehlivosti systemu kontinualniho cisteni vody primarniho okruhu JE s reaktorem VVER 440

Publishing Information

Journal Title
Jaderna Energie
Journal Volume
38
Journal Issue
5
Series
Jad. Energ.
Journal Page Range
170-176
ISSN
0448-116X
CODEN
JADEA

Optional Information

Notes
English translation available from Nuclear Information Center, 156 16 Prague-Zbraslav, Czechoslovakia, at USD 10.- per typewritten page.