Cone beam CT utilizing a rotational digital radiographic system. Early clinical experience on pulmonary and skeletal lesions
- 1. Tokushima Univ. (Japan). School of Medicine
Description
Utilizing a rotational digital radiographic system (SF-VA100, Hitachi), 289 digital images were obtained during a 360-degree rotation in 4.8 seconds. The images were transferred to a high-speed workstation and post-processed to create volume data in 9 minutes. The multi-planar reconstruction method reconstructed high-quality tomographic images with equal resolution in any direction. We applied this system as a cone beam CT in order to demonstrate pulmonary and spinal lesions. Early clinical experience suggested the usefulness of the method in the evaluation of diseases in organs with high radiographic contrast. (author)
Additional details
Publishing Information
- Journal Title
- Nippon Igaku Hoshasen Gakkai Zasshi
- Journal Volume
- 58
- Journal Issue
- 8
- Journal Page Range
- p. 451-453
- ISSN
- 0048-0428
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 29059476
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; BIOMEDICAL RADIOGRAPHY; CARCINOMAS; CAT SCANNING; COMPARATIVE EVALUATIONS; LUNGS; SKELETAL DISEASES; THREE-DIMENSIONAL CALCULATIONS; VERTEBRAE
- Descriptors DEC
- BODY; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DISEASES; EVALUATION; MEDICINE; NEOPLASMS; ORGANS; RESPIRATORY SYSTEM; SKELETON; TOMOGRAPHY