Published April 1979
| Version v1
Journal article
Influence of americium on the determination of plutonium
Creators
- 1. Commission of the European Communities, Karlsruhe (Germany, F.R.). European Inst. for Transuranium Elements
- 2. Alpha Chemie und Metallurgie G.m.b.H. (ALKEM), Hanau (Germany, F.R.)
Description
The effect of americium on the accuracy of plutonium determinations by the volumetric redox and constant potential coulometric methods has been investigated. In most volumetric methods up to 10% of americium does not interfere, only for the direct titration of plutonium (VI) with iron (II) a nonstoichiometric disturbance has been reported. In the constant potential coulometric method, hydrogen peroxide, which is present in older americium containing solutions as a product of radiolysis, results in high values during the reduction step and low values during the oxidation step. (Auth.)
Additional details
Additional titles
- Original title (German)
- Einfluss von Americium auf die Bestimmung des Plutoniums
Publishing Information
- Journal Title
- J. Nucl. Mater.
- Journal Volume
- 81
- Journal Issue
- 1-2
- Series
- J. Nucl. Mater.
- Journal Page Range
- 199-201
- ISSN
- 0022-3115
Conference
- Title
- Conference on characterization and quality control of nuclear fuels.
- Dates
- 13 - 15 Jun 1978.
- Place
- Karlsruhe, Germany, F.R.
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 10483952
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACCURACY; AMERICIUM; OXIDATION; PLUTONIUM; REDOX POTENTIAL; TITRATION; VOLTAMETRY
- Descriptors DEC
- ACTINIDES; CHEMICAL REACTIONS; ELEMENTS; METALS; TRANSPLUTONIUM ELEMENTS; TRANSURANIUM ELEMENTS