A Comprehensive Analysis of Cardiac Dose in Balloon-Based High-Dose-Rate Brachytherapy for Left-Sided Breast Cancer
- 1. Department of Radiation Oncology, Allegheny General Hospital, Pittsburgh, PA (United States)
- 2. Drexel University College of Medicine, Allegheny Campus, Pittsburgh, PA (United States)
Description
Purpose: To investigate radiation dose to the heart in 60 patients with left-sided breast cancer who were treated with balloon-based high-dose-rate brachytherapy using MammoSite or Contura applicators. Methods and Materials: We studied 60 consecutive women with breast cancer who were treated with 34 Gy in 10 twice-daily fractions using MammoSite (n = 37) or Contura (n = 23) applicators. The whole heart and the left and right ventricles were retrospectively delineated, and dose–volume histograms were analyzed. Multiple dosimetrics were reported, such as mean dose (Dmean); relative volume receiving 1.7, 5, 10, and 20 Gy (V1.7, V5, V10, and V20, respectively); dose to 1 cc (D1cc); and maximum point dose (Dmax). Biologic metrics, biologically effective dose and generalized equivalent uniform dose were computed. The impact of lumpectomy cavity location on cardiac dose was investigated. Results: The average ± standard deviation of Dmean was 2.45 ± 0.94 Gy (range, 0.56–4.68) and 3.29 ± 1.28 Gy (range, 0.77–6.35) for the heart and the ventricles, respectively. The average whole heart V5 and V10 values were 10.2% and 1.3%, respectively, and the heart Dmax was >20 Gy in 7 of 60 (11.7%) patients and >25 Gy in 3 of 60 (5%) patients. No cardiac tissue received ≥30 Gy. The V1.7, V5, V10, V20, and Dmean values were all higher for the ventricles than for the whole heart. For balloons located in the upper inner quadrant of the breast, the average whole heart Dmean was highest. The Dmean, biologically effective dose, and generalized equivalent uniform dose values for heart and ventricles decreased with increasing minimal distance from the surface of the balloon. Conclusions: On the basis of these comprehensive cardiac dosimetric data, we recommend that cardiac dose be routinely reported and kept as low as possible in balloon-based high-dose-rate brachytherapy treatment planning for patients with left-sided breast cancer so the correlation with future cardiac toxicity data can be investigated.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ijrobp.2011.02.058Additional details
Identifiers
- DOI
- 10.1016/j.ijrobp.2011.02.058;
- PII
- S0360-3016(11)00457-3;
Publishing Information
- Journal Title
- International Journal of Radiation Oncology, Biology and Physics
- Journal Volume
- 82
- Journal Issue
- 5
- Journal Page Range
- p. 1698-1705
- ISSN
- 0360-3016
- CODEN
- IOBPD3
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 44016596
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BALLOONS; BRACHYTHERAPY; DOSE RATES; GY RANGE 01-10; HEART; MAMMARY GLANDS; METRICS; NEOPLASMS; PATIENTS; PLANNING; RADIATION DOSES; TOXICITY; WOMEN
- Descriptors DEC
- ABSORBED DOSE RANGE; AIRCRAFT; ANIMALS; BODY; CARDIOVASCULAR SYSTEM; DISEASES; DOSES; FEMALES; GLANDS; GY RANGE; MAMMALS; MAN; MEDICINE; NUCLEAR MEDICINE; ORGANS; PRIMATES; RADIATION DOSE RANGES; RADIOLOGY; RADIOTHERAPY; THERAPY; VERTEBRATES
Optional Information