Published 1993 | Version v1
Book

The structural integrity safety case for Sizewell B power station

  • 1. Nuclear Electric plc, Knutsford (United Kingdom)

Description

This paper presents the safety case approach adopted for the components of the Sizewell 'B' Power Station for which a high degree of structural integrity is required. Such components include the Reactor Pressure Vessel, Steam Generator and Pressuriser for which Incredibility of Failure is claimed. The two parts of the case involve achievement and demonstration of integrity. This is achieved by extensive measures involving design, manufacture, materials and inspection. The demonstration has required a fracture mechanics approach. The specific role of inspection validation and its relation to critical defect size is described. (author)

Part of:
Nuclear power plant safety standards: towards international harmonization

Additional details

Publishing Information

Publisher
Mechanical Engineering Publications Ltd.
Imprint Place
London (United Kingdom)
ISBN
0 85298 860 5
Imprint Title
Nuclear power plant safety standards: towards international harmonization
Imprint Pagination
320 p.
Journal Issue
no. 1993-8
Series
Proceedings of the Institution of Mechanical Engineers (IMechE).
Journal Page Range
p. 149-157.

Conference

Title
towards international harmonization.
Acronym
International conference on nuclear power plant safety standards
Dates
26-28 Oct 1993.
Place
London (United Kingdom).

Optional Information