Published October 12, 2000 | Version v1
Report

Electromagnetic Borehole Flowmeter Testing in R-Area

Description

Six constant-rate, multiple-well aquifer tests were recently conducted in R-area to provide site-specific in situ hydraulic parameters for assessing groundwater flow and contaminant transport models of R-Reactor Seepage Basins (RRSB) plume migration and RRSB remedial alternatives. The pumping tests were performed in the Upper Three Runs and Gordon aquifers between December 1999 and February 2000. The tests provide reliable estimates of horizontal conductivity averaged over aquifer thickness, and a relatively large horizontal zone of influence. To complement these results, Electromagnetic Borehole Flowmeter (EBF) testing was subsequently performed to determine the vertical variation of horizontal conductivity for RPC-2PR, RPC-3PW, RPT-2PW, RPT-3PW, RPT-4PW and RPT-30PZ. The EBF data generally indicate significant aquifer heterogeneity over the tested screen intervals (Figures 14, 16-18, 20, 22, 24, 26 and 27-31). The vertical variation of groundwater flow in or out of the well screen under ambient conditions was also measured (Figures 13, 15, 19, 21, 23 and 25). These data have implications for contaminant monitoring

Availability note (English)

Available from PURL: https://www.osti.gov/servlets/purl/765407-5pPTMF/webviewable/

Additional details

Publishing Information

Imprint Pagination
[vp.]
Report number
WSRC-TR--2000-00170

Optional Information

Contract/Grant/Project number
AC09-96SR18500
Notes
This record replaces 31060769
Funding organization
US Department of Energy (United States)