Published March 1990 | Version v1
Journal article

Analytic reductions for transmission and leakage probabilities in finite tubes and hexahedra

  • 1. Ecole Polytechnique de Montreal, Inst. de Genie Energetique Montreal, Quebec H3C 3A7 (Canada)

Description

Analytic reductions are used to simplify evaluation of the transmission probabilities in a hexahedron and of the five independent probabilities (two transmission and three leakage probabilities) that are required for a finite tube. The four- and five-dimensional numerical integrations required for transmission and leakage probabilities are reduced to one and two dimensions, respectively

Additional details

Publishing Information

Journal Title
Nuclear Science and Engineering
Journal Volume
104
Journal Issue
3
Series
Nucl. Sci. Eng.
Journal Page Range
209-216
ISSN
0029-5639
CODEN
NSENA

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
21087634
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Descriptors DEI
ALGORITHMS; ANALYTICAL SOLUTION; LEAK TESTING; LOSS OF COOLANT; ONE-DIMENSIONAL CALCULATIONS; PROBABILISTIC ESTIMATION; REACTOR PHYSICS; TUBES; TWO-DIMENSIONAL CALCULATIONS
Descriptors DEC
ACCIDENTS; REACTOR ACCIDENTS; TESTING