Published March 1990
| Version v1
Journal article
Analytic reductions for transmission and leakage probabilities in finite tubes and hexahedra
Creators
- 1. Ecole Polytechnique de Montreal, Inst. de Genie Energetique Montreal, Quebec H3C 3A7 (Canada)
Description
Analytic reductions are used to simplify evaluation of the transmission probabilities in a hexahedron and of the five independent probabilities (two transmission and three leakage probabilities) that are required for a finite tube. The four- and five-dimensional numerical integrations required for transmission and leakage probabilities are reduced to one and two dimensions, respectively
Additional details
Publishing Information
- Journal Title
- Nuclear Science and Engineering
- Journal Volume
- 104
- Journal Issue
- 3
- Series
- Nucl. Sci. Eng.
- Journal Page Range
- 209-216
- ISSN
- 0029-5639
- CODEN
- NSENA
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 21087634
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Descriptors DEI
- ALGORITHMS; ANALYTICAL SOLUTION; LEAK TESTING; LOSS OF COOLANT; ONE-DIMENSIONAL CALCULATIONS; PROBABILISTIC ESTIMATION; REACTOR PHYSICS; TUBES; TWO-DIMENSIONAL CALCULATIONS
- Descriptors DEC
- ACCIDENTS; REACTOR ACCIDENTS; TESTING