Published March 1978 | Version v1
Report Restricted

Out-of-pile experiments with an electrical boiler for Acoustic Boiling Detection

Description

This report contains the experimental results of boiling tests obtained during the first testing phase in spring 1977 with an electrically heated 18-rod boiling generator installed in the sodium tank facility (NABEA) of IRE. The layout and performance of the boiling facility together with its instrumentation and criteria of selection of acoustic sensors for the detection of sodium boiling are described and discussed. The report provides information about the thermodynamics, blockage design and thermal conduction within the range of installation of the electric connecting head. The evaluation of the acoustic signals shows that boiling is indicated promptly and with a sufficiently high signal-to-noise ratio both by solid-born sensors and by high temperature microphones placed in the sodium

Availability note (English)

Available from INIS in electronic form

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Original title (German)
Out-of-pile Experimente mit einem elektrischen Siedegenerator zur akustischen Siededetektion

Publishing Information

Imprint Pagination
60 p.
Report number
KFK-PSB--01.02.18P01A

Optional Information

Notes
figs, refs, tabs
Secondary number(s)