Published 1973
| Version v1
Miscellaneous
Sizing of air cleaning systems for access to nuclear plant spaces
Description
A mathematical basis is developed to provide the practicing engineer with a method for sizing air-cleaning systems for nuclear facilities. In particular, general formulas are provided to relate cleaning and contamination dynamics of an enclosure such that safe conditions are obtained when working crews enter. Included in these considerations is the sizing of an air-cleaning system to provide rapid decontamination of airborne radioactivity. Multiple-nuclide contamination sources, leak rate, direct radiation, contaminant mixing efficiency, filter efficiencies, air-cleaning-system operational modes, and criteria for maximum permissible concentrations are integrated into the procedure. (author)
Availability note (English)
Available from Energoprojekt, Prague, Czechoslovakia.Additional details
Additional titles
- Original title (Czech)
- Dimenzovani systemu na cisteni vzduchu pro vstupy do prostoru jaderne elektrarny
Publishing Information
- Imprint Pagination
- 13 p.
- Report number
- CS-INIS--153
INIS
- Country of Publication
- Serbia and Montenegro
- Country of Input or Organization
- Serbia and Montenegro
- INIS RN
- 9368010
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- AIR; AIR CLEANING; AIR FILTERS; CONTAINMENT; CONTAMINATION; DECONTAMINATION; NUCLEAR POWER PLANTS; RADIATION PROTECTION; RADIOACTIVE AEROSOLS; RADIOACTIVITY; VENTILATION
- Descriptors DEC
- AEROSOLS; CLEANING; COLLOIDS; DISPERSIONS; FILTERS; FLUIDS; GASES; NUCLEAR FACILITIES; POLLUTION CONTROL EQUIPMENT; POWER PLANTS; SOLS; THERMAL POWER PLANTS
Optional Information
- Notes
- Translated from Nucl. Saf. (1973) v. 14(6) p. 634-642.
- Secondary number(s)