Sizing of air cleaning systems for access to nuclear plant spaces

Description

A mathematical basis is developed to provide the practicing engineer with a method for sizing air-cleaning systems for nuclear facilities. In particular, general formulas are provided to relate cleaning and contamination dynamics of an enclosure such that safe conditions are obtained when working crews enter. Included in these considerations is the sizing of an air-cleaning system to provide rapid decontamination of airborne radioactivity. Multiple-nuclide contamination sources, leak rate, direct radiation, contaminant mixing efficiency, filter efficiencies, air-cleaning-system operational modes, and criteria for maximum permissible concentrations are integrated into the procedure. (author)

Availability note (English)

Available from Energoprojekt, Prague, Czechoslovakia.

Additional details

Additional titles

Original title (Czech)
Dimenzovani systemu na cisteni vzduchu pro vstupy do prostoru jaderne elektrarny

Publishing Information

Imprint Pagination
13 p.
Report number
CS-INIS--153

INIS

Country of Publication
Serbia and Montenegro
Country of Input or Organization
Serbia and Montenegro
INIS RN
9368010
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
AIR; AIR CLEANING; AIR FILTERS; CONTAINMENT; CONTAMINATION; DECONTAMINATION; NUCLEAR POWER PLANTS; RADIATION PROTECTION; RADIOACTIVE AEROSOLS; RADIOACTIVITY; VENTILATION
Descriptors DEC
AEROSOLS; CLEANING; COLLOIDS; DISPERSIONS; FILTERS; FLUIDS; GASES; NUCLEAR FACILITIES; POLLUTION CONTROL EQUIPMENT; POWER PLANTS; SOLS; THERMAL POWER PLANTS

Optional Information

Notes
Translated from Nucl. Saf. (1973) v. 14(6) p. 634-642.
Secondary number(s)
P--1850/75.