Tests of the drift chamber system on the JINR synchrophasotron
Description
Determination of the basic characteristics of a drift-chamber system under real operation conditions is the aim of paper. The system of three 150x150 mm proportional chambers and four 200x200 mm drift chambers is in one-line operation with the NR-2116 V computer. The data are processed in two stages: determination of the transfer function parameters for the transition from the time values stored by the detecting electronic circuits to the coordinates of the particle trajectory points; determination of the accuracy and effectiveness of the drift chambers. The accuracy and effectiveness are calculated on the basis of track recognition. A set of points inside a 6 mm wide corridor including a subset of points from the drift chambers inside a 1.6 mm corridor is considered as a track. The total total number of points in a track should be at least 6; among them, at least three points should correspond to a drift chamber. The effectiveness of the drift chambers is found to be 99%. The spatial accuracy is 0.16 mm
Availability note (English)
MF available from INIS under the Report Number.Files
8344036.pdf
Files
(264.2 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:c965a655315a77a208424807fb8e5eb6
|
264.2 kB | Preview Download |
System files
(32.2 kB)
| Name | Size | Download all |
|---|
Additional details
Additional titles
- Original title (Russian)
- Исследование системы дрейфовых камер на синхрофазотроне ОИЯИ
Publishing Information
- Imprint Pagination
- 16 p.
- Report number
- JINR-R--13-9349
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 8344036
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ACCURACY; CAMAC SYSTEM; DATA PROCESSING; DIAGRAMS; DRIFT CHAMBERS; EFFICIENCY; ERRORS; ON-LINE MEASUREMENT SYSTEMS; PARTICLE TRACKS; TIMING CIRCUITS
- Descriptors DEC
- ELECTRONIC CIRCUITS; MEASURING INSTRUMENTS; MULTIWIRE PROPORTIONAL CHAMBER; ON-LINE SYSTEMS; PROPORTIONAL COUNTERS; RADIATION DETECTORS
Optional Information
- Notes
- 7 refs.; 11 figs.; submitted to Nucl. Instrum. Methods.